Enterprise Vault Admin Service fails to come online on a Veritas Cluster Service (VCS) cluster
book
Article ID: 100005315
calendar_today
Updated On:
Description
Error Message
VCS System log shows the following error:
VCS ERROR V-16-10051-6012 GenericService:EVSERVER-ENTERPRISEVAULTADMINSERVICE:online:Failed to wait for the service 'EnterpriseVaultAdminService' to start. Error = 258.
Cause
When starting the EV services the services may take longer than the VCS default online timeout
Resolution
To workaround the long delays, the VCS default online/offline timouts may be adjusted.
To do this, do the following:
- Open the Veritas Cluster Manager and login
- Expand the service group for Enterprise Vault
- Highlight the GenericService resource and click on the Show all attributes
- Look for OnlineWaitLimit attribute and double the value. This value may vary depending on certain environments.

Issue/Introduction
Enterprise Vault Admin Service fails to come online on a Veritas Cluster Service (VCS) cluster. No errors are logged in the Veritas Enterprise Vault Event log.
Was this article helpful?
thumb_up
Yes
thumb_down
No