Event ID 6980 & 6592 during archive run or manual archiving
book
Article ID: 100009394
calendar_today
Updated On:
Description
Error Message
Event ID: 6980 Error storing Saveset in Centera Collection temporary file location
Reason: The system cannot find the path specified. (0x80070003)
Saveset Id: 201304297260578~201304261917140000~Z~C09149B46270147C5F3F67A06A4346D1
V-437-6980
Event ID: 6592 Abnormal error occurred
VaultId: 1EB150654CB29704D976F72C1649442931110000kvsvault.com
Reference: GOPV/dt
V-437-6592
Cause
Collection folder was missing
Resolution
Confirm and Recreate the folder path:
- Open Properties of the Partition and select the Collection tab.
- Take note of the path and verify that it exists exactly the way it displays on the local sever.
- After creating the missing path and/or folder, restart the storage service.
- Test a manual archive and verify the events are no longer occurring.
Note: When there are multiple Vault Stores hosted by one server, verify that all the collection folder paths exist.
Issue/Introduction
During a scheduled archive run or a manual archive, the errors below will flood the Enterprise Vault (EV) event logs.