Event ID 41050 shows up in the event log during Mailbox archiving or provisioning operations or Event ID 6469 in event log when running the EVDominoExporter utility

book

Article ID: 100022021

calendar_today

Updated On:

Description

Error Message

Event ID 41050
Event ID 6469

Resolution


Event ID 41050 Mailbox archiving or provisioning operations

Resolution:
To resolve this issue, do the following:

 
1) Go to the Enterprise Vault server where Lotus Notes is installed.
 
2) In Windows Explorer, browse to the data directory of the Notes client.
 
3) Delete the cache.ndk file.
 
4) Retest the issue to verify that it is resolved.
 

 

 

Event ID 6469 EVDominoExporter utility error

The following error is seen in the Dtrace:

 
15 15:48:58.405 [13968] (EVDominoExporter) <13264> EV-L {DOMSESSION.EN_US} Creating mutex
 
16 15:48:58.405 [13968] (EVDominoExporter) <13264> EV-L {DOMSESSION.EN_US} Acquiring mutex
 
41 15:49:28.406 [13968] (EVDominoExporter) <13264> EV-L {DOMSESSION.EN_US} Unable to acquire mutex (258)
 
42 15:49:28.406 [13968] (EVDominoExporter) <13264> EV-M {DOMSESSION.EN_US} Error - unable to acquire mutex
 
43 15:49:28.406 [13968] (EVDominoExporter) <13264> EV-H {DOMSESSION.EN_US} DominoLibraryExceptions.DominoLibraryUnableInitializeSession: Failed to create Notes Session (mutex)|   at DomSession.Initialise()
 
44 15:49:28.406 [13968] (EVDominoExporter) <13264> EV:M CLogErr::Trace Ref: Event:An exception has occurred.   [Internal reference %1]   [0xc0041945] Status:Unspecified error  [0x80004005]|[0]: CDominoExporter|[1]: (null)|[2]: (null)|[3]: (null)|[4]: (null)|[5]: (null)
 
45 15:49:28.406 [13968] (EVDominoExporter) <13264> EV~E Event ID: 6469 An exception has occurred.| [Internal reference CDominoExporter] |
 
46 15:49:28.406 [13968] (EVDominoExporter) <13264> EV-M {DOMSESSION.EN_US} Terminating session...
 
47 15:49:28.406 [13968] (EVDominoExporter) <13264> EV-M {DOMSESSION.EN_US} Session was not initialized
 
51 15:49:29.187 [13968] (EVDominoExporter) <9204> EV:L CPools::~CPools (Entry) |
 
52 15:49:29.187 [13968] (EVDominoExporter) <9204> EV:M CPools::~CPools (Exit) |Success  [0] |
 
53 15:49:29.187 [13968] (EVDominoExporter) <9204> EV:M CEVAudit::Close Closing down the audit database.
 


Resolution:
 
1) Delete the cache.ndk file as above
 
2) Restart the server that contained the cache file that was deleted
 
3) Retest the issue to verify that the issue is resolved
 

 

 
 

 

Issue/Introduction

Event ID 41050 shows up in the event log during Mailbox archiving or provisioning operations or Event ID 6469 in the event log when running the EVDominoExporter utility.