Space in Vault Store fingerprint database log
The monitor terminated unexpectedly.
Details:
System.Runtime.InteropServices.COMException (0x80040E14):
Exception from HRESULT: 0x80040E14 at
KVS.EnterpriseVault.Interop.StorageManageClass.GetFPCDBTransactionLogSizes(String
siteEntryId, String& pBackupSettingsXML) at
KVS.EnterpriseVault.Monitoring.VSG_DB_TL_Size.RunNow(MonitorRunType runType) at
KVS.EnterpriseVault.Monitoring.MonitoringThreadBase.ScheduleThread()
Historically this was a monitored and valid resource used by Enterprise Vault. but system changes have removed the need for the applicable check but retained the orphaned information related to the resource in the database, producing a warning.
Search the MonitoringHistory table on the EnterpriseVaultDirectory database and look for the entry detailing the error. Using the information from the status message, the following query can narrow down the erroneous entry by modifying the Year, Month, and Day to reflect the values found in the warning. It is important to note that the date in the database is UTC while the date in the VAC status window is converted to local computer time. It might be necessary to adjust the time from the VAC to UTC for this query.
USE EnterpriseVaultDirectory
SELECT MonitoringHistoryIdentity, Source, StartDateUTC
FROM MonitoringHistory
WHERE YEAR(StartDateUTC) = 2011
AND MONTH(StartDateUTC) = 01
AND DAY(StartDateUTC) = 28
Using the source and date, identify the problematic entry and note the MonitoringHistoryIdentity associated with that item. Backup the EnterpriseVaultDirectory DB prior to making any modifications. Once backup is complete, use this MonitoringHistoryIdentity recorded above in the following query:
DELETE FROM MonitoringHistory WHERE MonitoringHistoryIdentity = ID_NUMBER