[System event log]
Source: Microsoft-Windows-DistributedCOM
Event ID: 10016
Description:
The application-specific permission settings do not grant Remote Launch permission for the COM Server application with CLSID
{F4D3EB5B-C7C5-11D1-90DB-0000F879BE6A}
and APPID
{95DCB63F-C982-11D1-90E0-0000F879BE6A}
to the user NT AUTHORITY\ANONYMOUS LOGON SID (S-1-5-7) from address 10.4.1.13. This security permission can be modified using the Component Services administrative tool.
V-437-10016
[Enterprise Vault event log]
Event ID: 41352
Task Category: Index Volumes Processor
Description: The processing of the Rebuild Sub task has stopped following errors.
Archive name: User 1
Task: Rebuild_2015-02-16_11:26:47_AM
Rebuild Sub task ID: 1E5B61E06AB7C9848902C7525A7E08A9D1110000evserver1_7
Reason: Undefined
Error Type: NonCritical
Description: Retrieving the COM class factory for remote component with CLSID {3A92686F-E5E8-4505-ABB5-49E5F725617A} from machine evserver1.EV.Local failed due to the following error: 80070005.
V-437-41352
Dtrace of EVIndexVolumesProcessor
{VAULTCOCREATEINSTANCEEX } Attempt [1] to create COM object failed. CLSID [{23228C7A-3C82-4A7D-948E-BE99EEF5991D}] Server Name [EVMail.Domain.in] Elapsed [0.016s] Result [Access is denied. (0x80070005)]
{VAULTCOCREATEINSTANCEEX } CLSID [{3A4119F2-3387-11D3-AD9F-0000F877C79D}] Server Name [EVAMAIL1] Used Server Name [EVMAIL1] Num of attempts [1] Total elapsed [0.007s] Result [Success (0)]
DCOM is disabled in the Enterprise Vault server or the Microsoft loopback check security feature that is designed to help prevent reflection attacks is enabled.
1. Verity that DCOM is enabled on Enterprise Vault Server.
2. Disable loopback check on the Enterprise Vault Server in the registry:
HKLM\SYSTEM\CurrentControlSet\Control\Lsa
Dword value: DisableLoopbackCheck
Value data (Decimal): 00000001
Warning: Incorrect use of the Windows registry editor may prevent the operating system from functioning properly. Great care should be taken when making changes to a Windows registry. Registry modifications should only be carried-out by persons experienced in the use of the registry editor application. It is also recommended that a complete backup of the registry and workstation / server be made prior to making any registry changes.
Note: For the BackConnectionHostNames value, add the Hostname, FQDN, and IP address (one entry per line).