Unable to log in to Data Insight Console due to DataInsightConfig service

book

Article ID: 100033005

calendar_today

Updated On:

Description

Error Message

Error excerpt:
Error occurred during login. Contact Administrator.

The following message may be found in the Webserver0.0.log:
WARNING: #{49} [LoginServiceImpl.login] [Internal Error] Login request failed for [username]@[domain]
WARNING: #{49} [LoginServiceImpl.login] Internal error during login
com.symc.matrix.core.QueryException:java.io.IOException: Error executing http method; code: 301

The following error may be found in the dscli0.0 log:
[DSUtility.logDlog] Cannot read configured domains from DI config service
 

Cause

The DataInsightConfig service is not started.

Resolution

Start the DataInsightConfig service and attempt to log into the console. The login should be successful once this service is started.

Issue/Introduction

A Data Insight user is unable to log in to a console, even if the correct credentials are used on the login page.