The following pair of Events is logged for each item that EV attempts to delete:
Type : Error
Event : 6760
Source : Enterprise Vault
Category : Storage Delete
Computer : myevserver.evlab.com
Description:
Error from EMC Centera FPLibrary
Function call: FPClip::Close(true)<fpclip_close(-)
</fpclip_close(-)
Status: FP_OBJECTINUSE_ERR (-10207)
Reason: FPClip still in use
Pool Address: 10.11.12.13,10.11.12.14?\\EMCPEASERVER\PEASHARE\EV_Profile1.pea
Type : Error
Event : 6469
Source : Enterprise Vault
Category : Storage Delete
Computer : myevserver.evlab.com
Description:
An exception has occurred.
[Internal reference CVault/DS/e]
v-437-6760
v-437-6469
This is caused by a problem with the way the expiry process calls the Centera API.
This error appears only in environments where all of the following are true:
This issue has been addressed in Enterprise Vault 12.4.1 and later.
When an item stored on an EMC Centera device become eligible for expiry, Storage Delete encounters errors when attempting to delete the item.
JIRA: CFT-1688