Clearwell EV Discovery fails with ' DirectoryConnectionObject CreateInstance failed'

book

Article ID: 100046959

calendar_today

Updated On:

Description

Error Message

<< EvCrawler_output log >>

[12044] ERROR root null - Error Context Begins:
[12044] ERROR root null -
DirectoryConnectionObject CreateInstance failed.  .\EsaEVSession.cpp(3351).

connectVaultDirectory failed. connectVaultDirectory failed. .\EsaEVSession.cpp(3320)
Session Initialization failed.

 .\EsaEVSession.cpp(3364).
[12044] ERROR root null - Adapter Error: Adapter error code: -2147221164
[12044] ERROR root null - Error Context En
ds.

 

Cause

The Enterprise Vault class files failed to register with the Windows operating system

 

Resolution

1. Navigate to D:\CW\Installer\distributions\x.x_Installer\packages\Symantec Enterprise Vault\1x.x.x
2. Select/Execute the Setup program > Next > Repair > Finish
3. Restart the eDP services

 

Issue/Introduction

Unable to run a successful Veritas EV Discovery. Within one minute of execution the task fails with
DirectoryConnectionObject CreateInstance failed